Macrolink Incorporated
1500 North Kellogg Drive
Anaheim, CA 92807, USA
Telephone: (714) 777-8800
Fax: (714) 777-8807
BBS 714-777-3898
E-mail: info@macrolink.com
http://www.macrolink.com
Product Information: Lori Martin
Sales/Marketing: Don Murray
Applications/Technical: Technical Support
Macrolink, Inc. is a premier supplier of communications, telecommunications, SCSI/mass storage and rugged and MIL enclosure products for commercial, ground mobile/fixed, avionics and shipboard applications. Founded in 1978, Macrolink is dedicated to the design and manufacture of sophisticated board level and related subsystem products. In all, over 100,000 units have been installed worldwide in virtually every computer application. Macrolink's philosphy is fundamental - design and build products which exceed the customers needs at a reasonable price with designed-in reliability. Experience shows that the cost of a product is not just the purchase price. Buying a reliable product reduces the true cost of ownership.
Mass Storage
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Host Adapter | Dual single-ended SCSI ports, P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/Re-select, >55MB/sec burst (D64). Model No. MVS/333 | Solaris HP-UX | ||
Host Adapter | As above but with single SCSI port and P2 connection. Model MVS/330 | Solaris HP-UX | ||
Host Adapter | Dual differential SCSI ports. P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/re-select, >55MB/sec burst (D64). Model No. MVS/344 | Solaris HP-UX | ||
Host Adapter | As above but with single SCSI port and P2 connection. Model MVS/340 | Solaris HP-UX | ||
Host Adapter | Dual SCSI ports: port 1 single-ended; port 2 differential. P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/re-select, >55MB/sec burst (D64). Model No. MVS/334 | Solaris HP-UX | ||
FAST/WIDE Host Adapter | 16bit, dual single-ended SCSI ports, P2 SCSI connection, 20MB/s sync, 10MB/s async per port, 68030 based, Initiator/Target, Disconnect/ReSelect, full SCSI-2 command support, >33MB/s DMA burst rates. Model No. MVS/233 | Solaris VxWorks HP-UX | ||
| As above, but single port w/P2 SCSI connection, Model No. MVS/230 | ||||
| As MVS/233, but dual differential port w/P2 SCSI connection, Model No. MVS/244 | ||||
| As above, but single differential port w/P2 SCSI connection, Model No. MVS/240 | ||||
FAST Host Adapter | 8bit, dual single-ended SCSI ports, P2 SCSI connection, 10MB/s sync, 5MB/s async per port, 68030, Init/Targ, Disconnect/ReSelect, full SCSI-2 command supp, >24MB/s DMA burst rates. Model No. MVS/211 | Solaris VxWorks HP-UX | ||
| As above, but single port w/P2 SCSI connection, Model No. MVS/210 | ||||
| As MVS/211, but dual differential port w/P2 SCSI connection, Model No. MVS/222 | ||||
| As above, but single differential port w/P2 SCSI connection, Model No. MVS/220 |
Serial I/O Boards
| Function | Description | Software Support | ADDR/DATA Width | Size |
|---|---|---|---|---|
High Density Communications Board | 16 line async Commux. Mix RS-232, RS-422, RS-485 and TTL. All lines available on P2. Low-cost. Line parameters independently programmable. Modem control on all lines. Model No. MVCS/16 | Solaris HP-UX | ||
| As above but in 8-line configuration. Model No. MVCS/08 | ||||
Async Serial I/O Commux | 16 line Async commux. Mix RS-232, RS-422, RS-423, RS-485 and MIL-STD-188, Modem control on all lines, 16 lines @ up to 115.2 KBaud, RISC based, up to 1MB dual-ported SRAM, line parameters independently programmable, DMA support. Model No. MVC/16 | Solaris VxWorks HP-UX | ||
| As above, but in an 8 line configuration, Model No. MVC/08 | ||||
Multiprotocol Communications Processor | 16 line Multi-Protocol proc, sync/async line-by-line, 16 lines @ 64KBaud simultaneously, up to 2Mbaud, HDLC/SDLC, BISYNC, onboard custom/classified protocol support, DMA support. Mix RS-232, RS-422, RS-485 and TTL, all lines avail on P2, Modem ctrl all ports, software development kit w/source in 'C' available, Model No. MVCP/16 | Code | ||
| As above, but sync/async in an 8 line configuration, Model No. MVCP/08 | ||||
High Speed Serial I/O Communications Processor | 16 channel sync/async processor, up to 12 Mbps serial rates, each channel independently programmable for port parameters and Sync/Async/Monosync/Bisync, HDLC/SDLC operation, MCF5102 ColdFire CPU w/quad MC68360s, DMA support. Mix RS-232, RS-422, RS-485 and TTL, all lines avail on P2, VxWorks BSP and software development kit w/source in 'C' available, Model No. MVCQuick | Code | ||
| As above, but in an 8 line configuration, Model No. MVCQ/08 |
Bus Interfaces
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
and Micro 5 | Interrupt Handler and Interrupter on any level, System Controller, VMEbus Arbiter, SYSRESET, SYSFAIL, SYSCLK generation, 512 interrupt queue for MUX/VMEbus, EDMA bus Slave to VMEbus, MUX bus Master to VMEbus, 68030 based, up to 5MB/s DMA burst rates | 6U |
Powered Enclosures
| Configuration | Available Slots | Description | Size |
|---|---|---|---|
Rack Mount Chassis | Monolithic J1/J2 backplane, 750 watt P/S, fully wired, fused, 2 removable drives w/ hot SCSI DisConnect (pat.pend.), mounting for two 5.25 in. fixed devices, filtered forced air, independent card cage/peripheral cooling, std 6U I/O panels (P/N 330200-53) | ||
| As above, but 4 removable drives w/ hot SCSI DisConnect (P/N 330200-50) | |||
Rack Mount Chassis | Monolithic J1/J2 backplane, 1000 watt, auto-ranging P/S w/.99 power correction, fully wired, fused, 2 removable drives w/ hot SCSI DisConnect, mounting for two 5.25 in. fixed devices, filtered forced air, indep card cage/peripheral cooling, std 6U I/O panels (P/N 330200-51) | ||
| As above, but 4 removable drives w/ hot SCSI DisConnect (P/N 330200-50) | |||
Rack Mount Chassis | Dual, independent 6 slot J1/J2 backplanes, dual 500 W P/S, fully wired, fused, two removable drives w/ hot SCSI DisConnect, mounting for two 5.25 in. fixed devices, filtered forced air, independent card cage/peripheral cooling, std 6U I/O panels (P/N 330250-51) | ||
| As above, but with 4 removable drives w/ hot SCSI DisConnect (P/N 330200-50) | |||
Portable Chassis | Portable VME chassis; high-resolution LCD display, 350 watt autoranging power supply, PS-2 or Sun Type 5 keyboard/trackball. Provisions for up to four fixed/removable devices. Forced air cooled | ||
Mass Storage Chassis | Rackmount enclosure providing four removable drive receivers with hot SCSI DisConnect, 200 watt heavy duty power supply, filtered forced air cooling and slide set (P/N 330140-55) | ||
| As above, but with 2 removable drive receivers w/hot SCSI DisConnect and mounting for one or two 5.25 in. fixed devices (P/N 330140-51) | |||
Drive Module | HC drive module assembly for all above enclosures; no disk drive. Module assembly accepts any 3.5 in. SCSI drive and provides shock and vibration isolation | ||
Tall | Environmentally sealed, conduction cooled, J1/J2 monolithic backplane, 80 watt power supply and 28VDC input power, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. ML-500 | ||
Long | Environmentally sealed, convection cooled, J1/J2 monolithic backplane, vertical load, 400 watt power supply, dual fans, EMI filtered, AC/DC input power. Mounts in ATR shock tray, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. ML-750 | ||
Long | Environmentally sealed, convection cooled, J1/J2 monolithic backplane, horizontal load, 500 watt power supply, dual fans, EMI filtered, AC/DC input power. Mounts in ATR shock tray, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. ML-1000 | ||
Long | Environmentally sealed, convection cooled, J1/J2 monolithic backplane, vertical load, 400 watt power supply, dual fans, EMI filtered, AC/DC input power. Mounts in ATR shock tray, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. ML-750 | ||
Long | Environmentally sealed, convection cooled, J1/J2 monolithic backplane, vertical load, 750 watt power supply, triple fans, EMI filtered, AC/DC input power. Mounts in ATR shock tray, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. ML-1500 | ||
Rackmount | Environmentally sealed, convection cooled, J1/J2 monolithic backplane, vertical load, 750 watt power supply, shock and vibration isolated card cage, AC/DC input power. Designed to MIL-461, 704, 810 and 5400T environments, Commercial, Ext. Temp, Rugged, MIL-SPEC versions, Model No. MRRC-18 |
Go to Product Function Index