ACQ INDUCOM Tel: +31-412-641922
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Board | Used to add a CompactFlash card slot to a 3U VMEbus System. CompactFlash is a small form factor card standard that encompasses CompactFlash (CF) flash data storage cards, magnetic disk cards and I/O cards. The board supports all of these types CompactFlash cards. Model Number VME1340 |
ACT/TECHNICO Tel: (215) 956-1200
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| Embedded Storage solution on PMC form factor. Standard ATA/IDE interface. Choice of one or two CF-II sockets. Front or rear I/O access. Five versions available. PMCStor P/N 925x | Linux Windows Solaris | |||
| Embedded 2.5 inch drive, available with either standard ATA/IDE up to 60GB or up to 17GB in solid state version. Enhanced Duty cycle versions for NEBS Level 3 - 7/24 requirements. PMCDis - P/N 9260 | Linux Windows Solaris | |||
SCSI | Disk Modules in 1, 2 or 3-slot widths, SCSI interface, wide variety of configurations and combinations available: Standard and Solid State hard disks, floppy, tape, DAT. Hard drives up to 300 GB each. Disk Modules - P/N: TDM series | Linux Windows Solaris | ||
| Network Attached Storage blade for striped or mirrored data. Supports RAID 0, 1, or 10 levels. For use in systems that support VITA 31.1 backplanes. RAIDStor - P/N 6200-XX | Windows Solaris |
CONCURRENT TECHNOLOGIES Tel: (734) 971-6309, +44 (0) 1206 752626
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Sub-System | EIDE disk drive module with 800MB to 4GB in a single slot. A 3.5 inch 1.44MB floppy drive and a printer interface are included. Model No. DS MSS/IFP | VxWorks QNX, Solaris |
MACROLINK Tel: (714) 777-8800
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Host Adapter | Dual single-ended SCSI ports, P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/Re-select, >55MB/sec burst (D64). Model No. MVS/333 | Solaris HP-UX | ||
Host Adapter | As above but with single SCSI port and P2 connection. Model MVS/330 | Solaris HP-UX | ||
Host Adapter | Dual differential SCSI ports. P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/re-select, >55MB/sec burst (D64). Model No. MVS/344 | Solaris HP-UX | ||
Host Adapter | As above but with single SCSI port and P2 connection. Model MVS/340 | Solaris HP-UX | ||
Host Adapter | Dual SCSI ports: port 1 single-ended; port 2 differential. P2 SCSI connection, 40MB/sec sync and 20MB/sec async, 68030 based. Disconnect/re-select, >55MB/sec burst (D64). Model No. MVS/334 | Solaris HP-UX | ||
FAST/WIDE Host Adapter | 16bit, dual single-ended SCSI ports, P2 SCSI connection, 20MB/s sync, 10MB/s async per port, 68030 based, Initiator/Target, Disconnect/ReSelect, full SCSI-2 command support, >33MB/s DMA burst rates. Model No. MVS/233 | Solaris VxWorks HP-UX | ||
| As above, but single port w/P2 SCSI connection, Model No. MVS/230 | ||||
| As MVS/233, but dual differential port w/P2 SCSI connection, Model No. MVS/244 | ||||
| As above, but single differential port w/P2 SCSI connection, Model No. MVS/240 | ||||
FAST Host Adapter | 8bit, dual single-ended SCSI ports, P2 SCSI connection, 10MB/s sync, 5MB/s async per port, 68030, Init/Targ, Disconnect/ReSelect, full SCSI-2 command supp, >24MB/s DMA burst rates. Model No. MVS/211 | Solaris VxWorks HP-UX | ||
| As above, but single port w/P2 SCSI connection, Model No. MVS/210 | ||||
| As MVS/211, but dual differential port w/P2 SCSI connection, Model No. MVS/222 | ||||
| As above, but single differential port w/P2 SCSI connection, Model No. MVS/220 |
MICRO MEMORY Tel: (818) 998-0070
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Fibre Channel Storage Controller | Quad Fibre Channel 2 Gb/sec VME Board with Dual RACE++ on P2 and 2GB-8GB of on-board SDRAM buffer memory. Features include a PowerPC processor, Gigabit Ethernet, VME64 master/slave interface and complete connectivity between all devices. Model Number MM-6466D | |||
Fibre Channel Storage Controller | Quad Fibre Channel 2 Gb/sec VME Board with Dual StarFabric on P2 and 2GB-8GB of on-board SDRAM buffer memory. Features include a PowerPC processor, Gigabit Ethernet, VME64 master/slave interface and complete connectivity between all devices. Model Number MM-6456D | |||
Storage Controller | Quad Fibre Channel 2 Gb/sec VME Board with 2GB-8GB of on-board SDRAM buffer memory. Features include a PowerPC processor, Gigabit Ethernet, VME64 master/slave interface and complete connectivity between all devices. Model Number MM-6446D |
PHOENIX INTERNATIONAL Tel: (714) 283-4800, (800) 203-4800
Fast Narrow Ultra SCSI Plug-In Storage Modules
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Solid State (Flash Memory) Disk Drive | Single slot SSD, capacities to 9GB with automatic internal active termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Commercial, Rugged versions. Model: V(F/M)1-350-SC-SSD-XXX, V(F/M)1-350-SC-SSD2-XXX | SCSI Transparent | ||
Single or Dual 810MB HDD | Single Slot slot, single or dual 810MB HDD with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)1-250-SC-D-810, V(F/M)1-250-SC-D2-810 | SCSI Transparent | ||
10GB, 20GB or 30GB HDD | Single Slot slot, 10.0GB, 20GB or 30.0GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)1-250-SC-D-10000, V(F/M)1-250-SC-D-20000, V(F/M)1-250-SC-D-30000 | SCSI Transparent | ||
or Dual 18.2GB HDD | 2 slot, single or dual 18.2GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-D-18200), V(F/M)2-350-SC-D2-18200 | SCSI Transparent | ||
Solid State (Flash Memory) Disk Drive | 2 slot SSD*, capacities to 18GB with automatic internal active termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. * devices can be doubled up or combined with any onther type drvice. Commercial, Rugged versions. Model: V(F/M)2-350-SC-SSD-XXX, V(F/M)2-350-SC-SSD2-XXX | SCSI Transparent | ||
30GB HDD and CD-ROM Drive | 2 slot, 20GB or 30GB HDD and CD-ROM with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-CD-20000, V(F/M)2-350-SC-CD-30000 | SCSI Transparent | ||
HDD and Floppy Disk | 2 slot, 18.2GB HDD and floppy disk drive with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-DF-18200 | SCSI Transparent | ||
HDD and Magneto-Optic Disk Subsystem | 2 slot, 18.2GB HDD and MO disk subsystem with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-DMO-18200 | SCSI Transparent | ||
HDD and 4-8GB QIC Tape Subsystem | 2 slot, 18.2GB HDD and 4-8GB QIC tape subsystem with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-DT-18200 | SCSI Transparent | ||
HDD w/12-24GB 4mm DDS-3 Tape Drive | 3 slot, 18.2GB HDD and 12-24GB DDS-3 DAT tape subsystem with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SC-DAT-18200 | SCSI Transparent |
Fast Wide Ultra SCSI Plug-In Storage Modules
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
18.2GB to 73.4GB HDD | 2 slot, removable 18.2GB, 36.7GB or 73.4GB HDD with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SCW-RHD-18200, V(F/M)2-350-SCW-RHD-36700, V(F/M)2-350-SCW-RHD-73400 | SCSI Transparent | ||
Solid State (Flash Memory) Disk Drive | 2 slot SSD*, capacities to 18GB with automatic internal active termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. * devices can be doubled up or combined with any onther type drvice. Commercial, Rugged versions. Model: V(F/M)2-350-SCW-SSD-XXX, V(F/M)2-350-SCW-SSD2-XXX | SCSI Transparent | ||
or Dual 18.2GB HDD | 2 slot, single or dual 18.2GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SCW-D-18200, V(F/M)2-350-SCW-D2-18200 | SCSI Transparent | ||
or Dual 36.4GB HDD | 2 slot, single or dual 36.4GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SCW-D-36400, V(F/M)2-350-SCW-D2-36400 | SCSI Transparent | ||
or Dual 73.4GB HDD | 2 slot, single or dual 73.4GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)2-350-SCW-D-73400, V(F/M)2-350-SCW-D2-73400 | SCSI Transparent | ||
or Dual 181.6GB HDD | 3 slot, single or dual 181.6GB with automatic internal termination, SCSI I/O via both P2 and Front Panel, user selectable ID and activity indicator. Model V(F/M)3-350-SCW-D-73400, V(F/M)3-350-SCW-D2-73400 | SCSI Transparent | ||
36.4GB, 73.4GB or 181.6GB HDD w/20-40GB 4mm LVD DAT Tape Drive | 3 Slot, 36.4GB, 73.4GB or 181.6GB HDD with 20-40GB 4mm LVD DAT Tape Drive with automatic internal termination, SCSI I/O via both P2 and front panel connector, user select device ID and activity indicator. Model V(F/M)3-350-SCW-DAT-18200, V(F/M)3-350-SCW-DAT-36400, V(F/M)3-350-SCW-DAT-73400, V(F/M)3-350-SCW-DAT-181600 | SCSI Transparent |
Rack Mount Storage Array, Fibre Channel, Ultra-160 SCSI
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| 3-Bay Multi Level RAID system to 360GB. Commercial, rugged versions. Model PSSR/XX-SC-XXX | ||||
| 3-Bay JBOD system to 540GB Commercial, rugged versions. Model PSS3/XX-SC-XXX | ||||
| 9-Bay Multi Level RAID system to 1.62TB Commercial, rugged versions. Model PRMR/XX-SC-XXX | ||||
| 9-Bay JBOD system to 1.98TB Commercial, rugged versions. Model PRMV/XX-SC-XXX |
RED ROCK TECHNOLOGIES Tel: (480) 483-3777, (800) 808-7837
Ultra Wide (16-bit) SCSI Mass Storage Modules
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Hard Drive Module | One Slot: SCSI Hard Drive Module: Up to 160GB capacity. Can configure one large drive or access separate drives via logical unit numbers. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SHAxx-LW | No Special Drivers Needed | ||
Flash Drive Module | One Slot: SCSI Flash Drive Module: Up to 20GB. Can configure one large drive or access via logical unit numbers. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SFAxx-LW | |||
ComboFlash/ Hard Drive Module | One Slot: Combo SCSI Flash Drive and Hard Drive Module: Various combinations such as 80GB Hard Drive and 10GB Flash Drive. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SHAxxSFAxx-LW | |||
SCSI to PCMCIA Module | One Slot: SCSI to PCMCIA adapter with two PCMCIA card slots. Each card slot able to receive Type I or II PCMCIA cards. Used with ATA Flash, ATA Hard Disk PCMCIA. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SP-LW | |||
SCSI to PCMCIA Module With Hard Drive | One Slot: SCSI to PCMCIA adapter with two PCMCIA card slots plus hard drive up to 80GB. Each card slot able to receive Type I or II PCMCIA cards. Used with ATA Flash, ATA Hard Disk PCMCIA. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SPSHAxx-LW | |||
SCSI to PCMCIA Module With Flash Drive | One Slot: SCSI to PCMCIA adapter with two PCMCIA card slots plus flash drive up to 10GB. Each card slot able to receive Type I or II PCMCIA cards. Used with ATA Flash, ATA Hard Disk PCMCIA. Auto termination, front panel and P2 SCSI I/O. Model: RRT-1SPSFAxx-LW | |||
One or Two Hard Drives | Two Slot Module: One or two hard drives up to 146GB each. SCSI I/O through Rows A and C of VMEbus P2 and optional front panel connector. Power from VMEbus. Model: RRT-2Hxx-LW | |||
Std Floppy | Two Slot Module: One hard drive up to 146GB and one standard floppy drive. SCSI I/O through Rows A and C of VMEbus P2. Power from VMEbus. Model: RRT-2HxxF1.44-W | |||
One or Two Flash Drives | Two Slot Module: One or two flash drives up to 34.8GB each. SCSI I/O through Rows A and C of VMEbus P2 and optional front panel connector. Power from VMEbus. Model: RRT-2FDxx-LW | |||
4mm DAT Tape Drive | Three Slot Module: One hard drive up to 146GB and one 4mm DAT drive up to 40GB. SCSI I/O through Rows A and C of VMEbus P2 and optional front panel connector. Power from VMEbus. Model: RRT-3HxxDxx-LW | |||
4mm AIT Tape Drive | Three Slot Module: One hard drive up to 146GB and one AIT drive up to 200GB. SCSI I/O through Rows A and C of VMEbus P2 and optional front panel connector. Power from VMEbus. Model: RRT-3HxxAITxx-LW |
SANRITZ AUTOMATION CO., LTD. Tel: +81-427-28-6123
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Hard Disk Module | Single VMEbus slot, 1.44MB 3.5 in. floppy drive, over 1GB 2.5 in. E-IDE hard disk, possible to use LPT, COM port and PC/104, option module for Sanritz SVA006/SVA007 boards, Model No. SVA201P | |||
Hard Disk Module | Single VMEbus slot, 1.44MB 3.5 in. floppy drive, over 1GB 2.5 in. IDE hard disk, SCSI-II, one PMC slot, option module for Sanritz SVA007 CPU board, Model No. SVA7001 |
VMETRO Tel: (281) 584-0728, +47 22 10 60 90
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
JBOD/RAID Storage Controller | Twin-Channel 2 Gigabits/sec JBOD & RAID Disk Recorder in a Single RACE++ Slot using Fibre Channel. 2 x 180 MB/s recording, 2 x 190 MB/s playback. Model No. Vortex VME | Linux | ||
JBOD | SANbric Rugged Storage System with dual 2 Ggigabit/sec fibre channel interfaces. Storage capacity of 1.8 Terabytes. Shock isolation options to match environmental requirements. Model No. SANbric | |||
JBOD/RAID Storage Controller | Front Panel Data Port Data Recording, Playback and Analysis Systems in a single VME slot using Fibre Channel. Single or Dual 2Gbps Optical Fibre Channel inferfaces for 180 or 385MB/s recording. Model No. MDR FPDP Recorder | |||
JBOD/RAID Storage Controller | Serial Front Panel Data Port Data Recording, Playback and Analysis Systems in a single VME slot using Fibre Channel. Single or Dual 2Gbps Optical Fibre Channel inferfaces for 180 or 385MB/s recording. Model No. MDR sFPDP Recorder | |||
JBOD/RAID Storage Controller | 1GHz Ultra Wideband Recording and Analysis System. 1GHz analog input via a dual channel 8-bit 1GHz ADC, up to 2GB/s recording rates with multi-purpose IO connectors for trigger, clock, reference and status control. Model No. UWB Recorder | web browser GUI |
VMIC Tel: (256) 880-0444, (800) 322-3616
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Disk | Single-slot VMEbus, 18 GB IDE Hard Drive, 3.5 in. 1.44MB Floppy Drive, 440 Mbyte IDE-flash memory options provide hard drive emulation, low power, flexible cable interconnect to CPU eliminates front panel clutter, or P2 cable option. Model No. VMIVME-7452 |
XYCOMVME Tel: (734) 944-1942
| Function | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Module | Single slot hard disk/floppy disk unit for use with Xycom VMEbus PC/AT processor modules. Includes 3.5 inch 1.44MB floppy disk drive and 2.1GB or larger, 2.5 inch IDE hard drive. Model No. XVME-977 | WinNT | ||
Module | Drive adapter module for XVME-65X processor products. Terminates VMEus P2 connector for floppy and hard drive connection into industry standard pinouts for using external drives. Mounts on back side of VMEbus P2. Model No. XVME-973 |