AcQ InduCom Tel: +31-412-641922
| Function | Description |
|---|---|
| Digital input module that will sample and selectively store up to 16 bits of digital data along with a 31-bit time stamp at a rate up to 5 MHz. The 31-bit time tag allows unique time tagging data. Model number M203 | |
Parallel Controller | Based on the Z8536 CIO. Capable of reading and writing 16 binary signals and can be programmed to generate interrupts when detecting transitions of the individual inputs. Model No. M318/MOD |
16x Isolated Sink Inputs | Capable of capturing typical 24V industrial signals. Each module has 16 binary inputs. A signal transition of each input can generate an interrupt. Interrupt can be issued if inputs match a pre-defined pattern. 3 timer/counters for transition counting, period measurement. Inputs optically isolated. Model No. M330/MOD |
16x Isolated Source Inputs | Capable of capturing typical 24V industrial signals. Each module has 16 binary inputs. A signal transition of each input can generate an interrupt. Interrupt can be issued if the inputs match a pre-defined pattern. 3 timer/counters for transition counting, period measurement. Inputs optically isolated. Model number M331/MOD |
16x Isolated Sink Outputs | Capable of sinking 16 binary outputs. For typical applications the module has 3 programmable timers. 3 different output modes are available: pulse, one shot and square wave. Timer outputs connected to outputs of the module. Model No. M332/MOD |
16x Isolated Source Outputs | Capable of sourcing 16 binary outputs. For typical applications the module has 3 programmable timers. 3 different modes are available: pulse, one shot and square wave. Timer outputs connected to outputs of the module. Model No. M333/MOD |
with Emergency Shut-off | Eight monostable relays with 2 throw over contacts each. One throw over contact is available at front connector, while the other contact is used for reading back the relay state. Maximum continuous current for the relays is 1A. Maximum switching voltage is 250Vac/220Vdc.Model number M338/MOD |
Men Mikro Elektronik Tel: +49 911-99335-0, (972) 939-2675
| Function | Description |
|---|---|
| 8 outputs, source, 2A, isolated, 25-pin DSUB or screw terminal/LEDs, Commercial, Ext. Temp versions, Model No. M22 | |
| 16 inputs, sink/source, Schmitt trigger characteristics, isolated, 25-pin DSUB or screw terminal/LEDs, Commercial, Ext. Temp versions, Model No. M24 | |
| 16 outputs, sink, isolated, Commercial, Ext. Temp versions, Model No. M27 | |
| 16 outputs, source, isolated, Commercial, Ext. Temp versions, Model No. M28 | |
| 16 inputs, sink, isolated, Commercial, Ext. Temp versions, Model No. M31 | |
| 16 inputs, source, isolated, Commercial, Ext. Temp versions, Model No. M32 | |
| 8 relay outputs, Commercial, Ext. Temp versions, Model No. M43 | |
and Out | 32 inputs or 16 in and 16 out (500mA each), 2 DSPs (32MIPS each), 160kb memory, isolation, Commercial, Ext. Temp versions, Model No. M63 |
and Out | 32 inputs and/or outputs, isolated, 500mA per channel, Commercial, Ext. Temp versions, Model No. M66 |
| 16 opto-relay outputs, 0..36V output voltage per channel, 500mA output current per channel, Thermal and short-circuit protection, Load on supply voltage, Optical isolation from the system (500VDC), Optical isolation between the channels (100VDC). Model No. M81 | |
| 16 fast 20kHz inputs, 0..40V input voltage, Constant current inputs, Hysteresis function, Interrupt generation, Load on ground, Optical isolation from the system (500VDC), Optical isolation between the channels (100VDC). Model No. M82 | |
| 16 relay outputs, Commercial, Ext. Temp versions, Model No. M56 | |
| 32bit TTL I/O, isolated, Commercial, Ext. Temp versions, Model No. M58 |