VMEbus to MIL-STD-1553, 1773 Interfaces

ACQ INDUCOM Tel: +31-412-641922
VMEbus To:DescriptionSoftware
Support
ADDR/
DATA
Width
Size
Two Channel
MIL-STD-1553
Intelligent interface card for two channel, dual redundant MIL-STD-1553 applications. MIL-STD-1553 test, simulation and bus analysis. 1553A, 1553B, McAir and STANAG 3838 variants in a single card. Each channels supports concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with Bus Monitor (BM). Additional stand-alone Chronological Bus Monitor (CBM) facility is provided, with comprehensive multi-level triggering capability. Full error injection in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. Two variable amplitude dual redundant 1553 interfaces. 8 Mbytes of dual ported RAM on each channel. C drivers in source code and Windows menu driven software. Model Number VME2303
.
.
3U

AIM GmbH Tel: +49 761 45229-0
VMEbus To:DescriptionSoftware
Support
ADDR/
DATA
Width
Size
MIL-STD-1553
Test & Simulation Modules for MIL-STD-1553 to VMEbus. Dual Redundant, Single or Dual Stream configurations: Concurrent BC, 31 RTs & BM Operation, Full Error Injection/ Detection Capability, On-board Application Support Processor, Multi-level Trigger for Capture/Filtering, IRIG-B Time Decoder for Data Correlation, Real Time Recording. Model No. AVI1553-1/2, AVI1553S-1/2 (Simulator Only), AVI1553M-1/2 (Single Function Version)
C/C++
Source Code
VxWorks
IRIX
A32:D64
6U
STANAG
3910/EFEX
Test & Simulation Modules for STANAG3910 and EFEX (EFAbus Express) to VMEbus. Single Stream HS/LS configuration, Concurrent HS/LS BC, 31 RT's & BM Operation, Full HS & LS Error Injection/ Detection Capability, Multi-level HS/LS Trigger for Capture/ Filtering, IRIG-B Time Decoder for Data Correlation, Real Time Recording & Physical Bus Replay, VOX-C Fibre Optic Front End (FOFE) VMEbus Module included. VOX3910-CTX-V option for EFAbus Optical Validation. A Modification Kit to take the card from standard EFA to EFEX, EFAbus Express mode is available. Also available with an 'Electrical Front End' to support the French 'Rafale' aircraft project. Model No. AVI3910, AVI3910S (Simulator Only), AVI3910M (Monitor Only), AVI3910-XP (supports EFAbus Express with 'Dual Mode')
C/C++
Source Code
VxWorks
IRIX
A32:D64
6U

ALPHI TECHNOLOGY Tel: (480) 838-2428
VMEbus To:DescriptionSoftware
Support
ADDR/
DATA
Width
Size
MIL-STD-1553
Dual redundant, UTMC Summit, BCRTM, 64Kword SRAM, Tagging, Multi-messages, Simultaneous Remote Terminal and Monitor modes, -40 to 85 degrees C, Model No. COM-1553-3
C Source
Driver
.
3U
MIL-STD-1553
Dual redundant, UTMC Summit, BCRTM, 64Kword SRAM, Tagging, Multi-messages, Simultaneous Remote Terminal and Monitor modes, -40 to 85 degrees C, Model No. COM-1553-6
C Source
Driver
.
6U

SBS TECHNOLOGIES Tel: (505)-875-0600
VMEbus To:DescriptionSoftware
Support
ADDR/
DATA
Width
Size
MIL-STD-1553
Flexible, full function, up to 2 dual redundant MIL-STD-1553 channels, including concurrent and independent operation of a Bus Controller (BC), 31 Remote Terminals (RT), and dual function Bus Monitor (BM). Optional 48-bit IRIG-B clock input. Commercial and extended temperature versions. Model No. ABI-V6
.
.
6U
MIL-STD-1553
Full Function, Bus Controller (BC), 31 Remote Terminals (RT), and dual function Bus Monitor (BM). 2 dual redundant MIL-STD-1553 channels, Optional 48-bit IRIG-B clock input. Model No. ABI-V7
.
.
6U
MIL-STD-1553
Full Function, Bus Controller (BC), 31 Remote Terminals (RT), and dual function Bus Monitor (BM). Up to 4 dual redundant MIL-STD-1553 channels. Optional 48-bit IRIG-B clock input. Extended temperature and conduction cooled versions. Model No. ABI-V6-3/4
.
.
6U
MIL-STD-1553
Full Function, Bus Controller (BC), 31 Remote Terminals (RT), and dual function Bus Monitor (BM). Up to 2 dual redundant MIL-STD-1553 channels. Optional 48-bit IRIG-B clock input. Extended temperature and conduction cooled versions. Model No. ABI-V6CC
.
.
6U
MIL-STD-1553
Full Function, Bus Controller (BC), 31 Remote Terminals (RT), and dual function Bus Monitor (BM). For high-performance simulation applications where very fast data transfers between the host and the interface are required. Dual redundant MIL-STD-1553 Master/Slave interface to the VMEbus backplane. Automated buffer transfers to and from host memory. DMA transfers free the host processor from time consuming polling or interrupt handling. Optional 48-bit IRIG-B clock input. 2 MB additional Memory available. Model No. ABI-V5
.
.
6U
MIL-STD-1553
Advanced Single Function (ASF), Bus Controller (BC), Remote Terminal (RT), or dual function Bus Monitor (BM). Available with one to four channels, Optional 48 bit IRIG-B clock input, Extended temperature and multiple RT versions. Model No. ASF-V6-1/2
.
.
6U
MIL-STD-1553
Advanced Single Function (ASF), Bus Controller (BC), Remote Terminal (RT), or dual function Bus Monitor (BM). Available with one to four channels. Optional 48 bit IRIG-B clock input. Model No. ASF-V6-3/4
.
.
6U
MIL-STD-1553
Advanced Single Function (ASF), Bus Controller (BC), Remote Terminal (RT), or dual function Bus Monitor (BM). Available with one to four channels. Optional 48 bit IRIG-B clock input. Extended temperature, conductive cooled, and multiple RT versions. Model No. ASF-V6CC
.
.
.

VMIC Tel: (256) 880-0444, (800) 322-3616
VMEbus To:DescriptionSoftware
Support
ADDR/
DATA
Width
Size
MIL-STD 1553
Provides 128K x16-bits of dual-port RAM for constructing control block information and storing transmitted and received 1553 bus data. Can function as a Bus Controller/Simulator, Multiple Remote Terminal and/or Monitor. Model No. VMIVME-6000
VMISFT-
9491
A32:D16
6U


Return To Bus Interfaces Index / Return To VME Index By Product Function / Return To VME Directory Main Page