ACQ INDUCOM Tel: +31-412-641922
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Controller | Based on one or four SJA1000 CANbus controllers. Each SJA1000 provides an interface to the popular CANbus that supports both standard (11-bit) and extended (29-bit) identifier fields. Front panel LEDs provide diagnostical network information. Provides one or four CANbus interfaces. The CAN network is a serial communication protocol which efficiently supports distributed control with a high level of reliability. Model No. VME1360(3U) or VME360(6U) | 6U | ||
Controller | Based on one or four Motorola MC68763s featuring the TouCAN module for advanced CANbus protocol support. Board is ideally suited for executing high-level CANbus protocol stacks without loading the host CPU. The CANbus is optically isolated from the system according to the ISO11898 standard. Model Number VME1376(3U) or VME376(6U) | 6U |
AIM GmbH Tel: +49 761 45229-0
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Serial Link | Supports 8Tx and 8Rx Serial Data Channels, Autonomous Transmit Sequencing, Continuous Clock & Data Transmission, Transmission Frequency of 64KHz or 62.5KHz, Full Error Injection on each Tag Transfer, Decode 16bit Data & Status Words, Tag orientated & Chronological Data Storage, Tag Selective Data Filtering, Full Error Detection, Programmable Interrupts & Triggers, On-board Application Support Processor, IRIG-B Time Tagging. Model No. AVI-PSI-16 | Source Code |
CAEN S.p.A. Tel: +39 0584 388 398
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Bridge | No boot required, ready at power ON; up to 30 MByte/s sustained data transfer rate; VME Master (arbiter or requested); VME Slave (register and test RAM access); cycles: RW, RMW, BLT, MBLT, IACK, ADO, ADOH; addressing: A16, A24, A32, CR/CSR, LCK; data width: D8, D16, D32, D64; system controller capabilities, interrupt handler; front panel Dataway Display (avaiable also fron PC and VME); 5 outputs and 2 inputs, NIM or TTL, fully programmable; VME 64X Backplane required. Model No. VX1718 | 2000/XP Linux | ||
Optical Link Bridge | No boot required, ready at power ON; daisy chain capability; PCI 32bit/33MHz; up to 70 MByte/s sustained data transfer rate;VME Master (arbiter or requested); VME Slave (register and test RAM access); cycles: RW, RMW, BLT, MBLT, IACK, ADO, ADOH; addressing: A16, A24, A32, CR/CSR, LCK; data width: D8, D16, D32, D64; system controller capabilities, interrupt handler; front panel Dataway Display (avaiable also fron PC and VME); 5 outputs and 2 inputs, NIM or TTL, fully programmable; VME 64X Backplane required. Model No. VX2718 | 2000/XP Linux | ||
Parallel Port Interface | Basic VME master operations supported; easy debug of VME modules from PC parallel port interface;LED display of VME bus activity; AS, DS0,DTACK,BERR and IACKOUT panel outputs; 300 Kbytes/s transfer rate in BLT cycle; stand alone configuration supported. Model No. V718 | |||
| USB-VME Bridge. Easy VME control: you just need to plug the module in the crate and to connect it to an USB port on your PC. No boot required; USB2.0; up to 30MB/s; master; slave; VME64 and VME64X versions; system controller; interrupt handler; front-panel display; 7 I/O programmable; Software in C, Visual Basic, LabView. Model No. V1718 | 2000/XP Linux | |||
| PCI-VME Bridge. The bridge consists of three parts: a PCI card (A2818), a VME module (V2718) and an optical fibre. For multi-crate control, you just need to add one more V2718 for each additional crate and connect them in daisy chain via optical fibres. No VME boot required; PCI32bit/33MHz; up to 50MB/s; master; slave; VME64 and VME64X versions; system controller; interrupt handler; front-panel display; 7 I/O programmable; Software in C, Visual Basic, LabView. Model No. V2718 - A2818 | 2000/XP Linux |
CES-CREATIVE ELECTRONIC SYSTEMS Tel: +41.22.884.51.00
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| 1100 MBytes/s sustained PCI-to-PCI intercrate transparent connection, available in VME, PMC and PCI (Workstation) form factors, shared and mirrored memory, inter-processor synchronization, broadcast, autonomous DMA channels supporting chained block transfers, 15 nodes over 20 meters extendable to up to 200 meters (fibre optic), connection to GTL, differential or optical interfaces. Model No. PVIC 8025 | VxWorks Linux |
DYNATEM Tel: (949) 855-3235
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| Low cost adapter to PC/104 bus lets user integrate specialty boards like speech synthesizers and multi media cards in VMEbus chassis. Model No. DPC104 |
ESD Tel: (800) 732-8006, +49-511-372980
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| Contains up to 4 CAN interfaces acc. to ISO11898, each optoisolated from the others and equipped with its own microcontroller MC68331. Data transfer rate up to 1 Mbit/s. Running CAN 2.0A/B and CANopen. VME64x connector. Model No. VME-CAN4 | Linux RTOS UH | |||
| Contains up to 4 DeviceNet interfaces, each optoisolated from the others and equipped with its own microcontroller MC68331. All DeviceNet data transfer rates supported. On-board DeviceNet firmware, master/slave. VME64x connector. Model No. VME-CAN4-4DN | Linux RTOS UH |
GENERAL STANDARDS Tel: (256) 880-8787
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| High speed parallel link, compatible with message passing protocol, Model No. MB2-LINK-VME | ||||
| High speed parallel link to PMC and/or PCI. VME transfer rate of 56MB/sec (D64), cable rate of 80 to 160MB/sec | DOS |
HYTEC ELECTRONICS Tel: +44 (0) 118 9757770
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| VME-VXI Adaptor; C size; extends and buffers the VME subset of the VXI Bus and allows a VME processorcard to access VXI. It includes a VME slave interface, VXI configuration registers and controls for the MODID lines. High current bi-directional drivers connect the two busses. The module accepts and stores multiple concurrent interrupts from the VXI Bus. Model No. VVA4032 |
KONTRON MODULAR COMPUTERS Tel: +49-8341-803-0
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
Dual Profibus Master | Intelligent VMEbus controller, Profibus DP master class 1 and 2, FMS master/slave functionality, MC68360-CPU, ASPC-2, firmware in Flash, DP-RAM for VMEbus access, 2 independent Profibus interfaces, max. 12 MBaud. Model No. VPFB | VxWorks | ||
Profibus Slave | Industrial I/O module for VMEbus based systems utilizing plug-in fieldbus modules for CAN or PROFIBUS operation. Model No. VME-FM | VxWorks |
MACROLINK Tel: (714) 777-8800
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
and Micro 5 | Interrupt Handler and Interrupter on any level, System Controller, VMEbus Arbiter, SYSRESET, SYSFAIL, SYSCLK generation, 512 interrupt queue for MUX/VMEbus, EDMA bus Slave to VMEbus, MUX bus Master to VMEbus, 68030 based, up to 5MB/s DMA burst rates |
SBS TECHNOLOGIES Tel: (505)-875-0600
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| VME to PCI connectivity and fiber-optic capabilities. Connects the VMEbus and PCI bus creating a virtual bus that allows the two systems to operate as one, enabling seamless operation and the combined benefits of two diverse systems. Provides loopback diagnostics for PIO transfers. Memory and I/O mapping. Bidirectional bus mastership. Controller Mode DMA data rates up to 35 MB/s; Slave Mode DMA transfer rates up to 13 MBs. Model No. 618-3 | ||||
| VME to PCI connectivity with copper interface. Memory and I/O mapping. Bidirectional bus mastership. VMEbus system controller mode. Model No. 616 | ||||
for Broadcast Memory | Allows a common shared memory to be shared by all computers on the network. Data written to the local computer's memory are broadcast to the hub and written to all networked computers' memories simultaneously. Available with with 4MB, 8MB, or no shared memory. Supports fiber-optic cable up to 150 meters. Model No. 2516 |
VMIC Tel: (256) 880-0444, (800) 322-3616
| VMEbus To: | Description | Software Support | ADDR/ DATA Width | Size |
|---|---|---|---|---|
| Host Computer Interface: Interface VMEbus to DEC, Concurrent, Sun Workstations, Harris, IBM PC/AT, Multibus II; interface to high resolution graphics terminals; byte and word-swapping. Model No. VMIVME-DR11W-A | Solaris System V IRIX Harris CX/UX VxWorks | |||
| Intelligent Encore HSD Compatible HSD Interface: Automatic execution from interpreted IOCBs. Supports external mode. Model No. VMIVME-5620 | Solaris IRIX VxWorks | |||
| SGI-VMEbus Adapter. Connectivity between Silicon Graphics Multiprocessor Computer (CHALLENGE and Onyx Series) and 6U VMEbus. Model No. VMIVME-5522L |